Standard:
Applicable and Compliant Standards:

PVC Insulated, Non-sheathed Cable

  • Standard:
    BS EN 50525-2-31
  • Certification Body:
    BASEC
  • Structure:
    Cu / PVC
  • Type:
    6491X, H07V-U, H07V-R, H07V-K
  • Core:
    1
  • Operating Voltage Range:
    450/750V
  • Operating Temperature:
    -15°C - +70°C
  • Cross Section Area:
    H07V-U: 1.5-10mm²
    H07V-R: 1.5-630mm²
    H07V-K: 1.5-240mm²
  • Catalog:
  • Certification:
Applicable and Compliant Standards:

PVC Insulated, Non-sheathed, High-temperature Cable

  • Standard:
    BS 6231
  • Certification Body:
    BASEC
  • Structure:
    Cu / PVC
  • Core:
    1
  • Operating Voltage Range:
    600/1000V
  • Operating Temperature:
    -15°C - +105°C
  • Cross Section Area:
    0.5-240mm²
  • Catalog:
  • Certification:
Applicable and Compliant Standards:

PVC Insulated, PVC Sheathed Cable

  • Standard:
    BS 6004
  • Certification Body:
    BASEC
  • Certified Specs:
    Solid: 1.0-2.5mm²
    Stranded: 4-35mm²
  • Structure:
    Cu / PVC / PVC
  • Type:
    6181Y
  • Core:
    1
  • Operating Voltage Range:
    300/500V
  • Operating Temperature:
    -15°C - +70°C
  • Cross Section Area:
    1.0-35mm²
  • Catalog:
  • Certification:
Applicable and Compliant Standards:

PVC Insulated, PVC Sheathed Cable

  • Standard:
    BS 6004
  • Certification Body:
    ECM
  • Structure:
    Cu / PVC / PVC
  • Type:
    6181Y, BVV
  • Core:
    1
  • Operating Voltage Range:
    300/500V
  • Operating Temperature:
    -15°C - +70°C
  • Cross Section Area:
    1.5-35mm²
  • Catalog:
  • Certification:
Applicable and Compliant Standards:

PVC Insulated, PVC Sheathed, Flat Wiring Cable

  • Standard:
    BS 6004
  • Certification Body:
    BASEC
  • Certified Specs:
    Solid: 1.0-2.5mm²/C
    Stranded: 4-16mm²/C
  • Structure:
    Cu / PVC / PVC
  • Type:
    6192Y, 6193Y
  • Core:
    2, 3
  • Operating Voltage Range:
    300/500V
  • Operating Temperature:
    -15°C - +70°C
  • Cross Section Area:
    1.0-16mm²
  • Catalog:
  • Certification:
Applicable and Compliant Standards:

PVC Insulated, PVC Sheathed, Flat Wiring Cable

  • Standard:
    BS 6004
  • Certification Body:
    ECM
  • Structure:
    Cu / PVC / PVC
  • Type:
    6192Y, BVVB
  • Core:
    2
  • Operating Voltage Range:
    300/500V
  • Operating Temperature:
    -15°C - +70°C
  • Cross Section Area:
    1.0-6mm²
  • Catalog:
  • Certification:
Applicable and Compliant Standards:

PVC Insulated, PVC Sheathed, Flat Wiring Cable with Circuit Protective Conductor

  • Standard:
    BS 6004
  • Certification Body:
    BASEC
  • Certified Specs:
    Solid: 1.0-2.5mm²/C
    Stranded: 4-16mm²/C
  • Structure:
    Cu / PVC / PVC + CPC
  • Type:
    6241Y, 6242Y, 6243Y
  • Core:
    1, 2, 3
  • Operating Voltage Range:
    300/500V
  • Operating Temperature:
    -15°C - +70°C
  • Cross Section Area:
    1.0-16mm²
  • Catalog:
  • Certification:
Applicable and Compliant Standards:

PVC Insulated, PVC Sheathed, Flat Wiring Cable with Circuit Protective Conductor

  • Standard:
    BS 6004
  • Certification Body:
    ECM
  • Structure:
    Cu / PVC / PVC + CPC
  • Type:
    6242Y, BVVB
  • Core:
    2
  • Operating Voltage Range:
    300/500V
  • Operating Temperature:
    -15°C - +70°C
  • Cross Section Area:
    1.0-6mm²
  • Catalog:
  • Certification:
Applicable and Compliant Standards:

XLPE Insulated, PVC Sheathed, Unarmoured Cable

  • Standard:
    BS 7889
  • Certification Body:
    BASEC
  • Certified Specs:
    1C: 10–1000 mm²
    2–4C: 1.5–120 mm²/C
  • Structure:
    Cu / XLPE / PVC
  • Core:
    1, 2, 3, 4
  • Operating Voltage Range:
    600/1000V
  • Operating Temperature:
    -15°C - +90°C
  • Cross Section Area:
    1C: 1.5-1000mm²
    2-4C: 1.5-400mm²
  • Catalog:
  • Certification:
Applicable and Compliant Standards:

XLPE Insulated, PVC Sheathed, Aluminum Wire Armour(AWA) Cable

  • Standard:
    BS 5467
  • Certification Body:
    BASEC
  • Structure:
    Cu / XLPE / AWA / PVC
  • Type:
    6941X
  • Core:
    1
  • Operating Voltage Range:
    600/1000V
  • Operating Temperature:
    -15°C - +90°C
  • Cross Section Area:
    50-1000mm²
  • Catalog:
  • Certification:
Applicable and Compliant Standards:

XLPE Insulated, PVC Sheathed, Galvanized Steel Wire Armour(SWA) Cable

  • Standard:
    BS 5467
  • Certification Body:
    BASEC
  • Structure:
    Cu / XLPE / SWA / PVC
  • Type:
    6942X, 6943X, 6944X, 6947X, 6940/12X, 6940/19X, 6940/27X, 6940/37X
  • Core:
    2, 3, 4, 7, 12, 19, 27, 37
  • Operating Voltage Range:
    600/1000V
  • Operating Temperature:
    -15°C - +90°C
  • Cross Section Area:
    2-4C: 1.5-400mm²/C
    ≥7C: 1.5-4mm²/C
  • Catalog:
  • Certification:
Applicable and Compliant Standards:

LSOH Insulated, Non-sheathed Cable

  • Standard:
    BS EN 50525-3-41
  • Certification Body:
    BASEC
  • Certified Specs:
    H07Z-U: 1.5-10mm²
    H07Z-R,H07Z-K: 1.5-240mm²
  • Structure:
    Cu / LSOH
  • Type:
    H07Z-U, H07Z-R, H07Z-K
  • Core:
    1
  • Operating Voltage Range:
    450/750V
  • Operating Temperature:
    -15°C - +90°C
  • Cross Section Area:
    H07Z-U: 1.5-10mm²
    H07Z-R: 1.5-630mm²
    H07Z-K: 1.5-240mm²
  • Catalog:
  • Certification:
Applicable and Compliant Standards:

XLPE insulated, LSOH Sheathed, Unarmoured Cable

  • Standard:
    BS 8573
  • Certification Body:
    BASEC
  • Certified Specs:
    10-1000mm²
  • Structure:
    Cu / XLPE / LSOH
  • Core:
    1
  • Operating Voltage Range:
    600/1000V
  • Operating Temperature:
    -15°C - +90°C
  • Cross Section Area:
    1.5-1000mm²
  • Catalog:
  • Certification:
Applicable and Compliant Standards:

XLPE Insulated, LSOH Sheathed, Unarmoured Cable

  • Standard:
    IEC 60502-1
  • Certification Body:
    BASEC
  • Certified Specs:
    2-4C: 1.5-400mm/C²
  • Certification Body:
    ECM
  • Certified Specs:
    1C: 1.5-1000mm²
    2-5C: 1.5-400mm/C²
    7-37C: 1.5-4mm/C²
  • Structure:
    Cu / XLPE / LSOH
  • Core:
    1, 2, 3, 4, 5, 6, 7
  • Operating Voltage Range:
    600/1000V
  • Operating Temperature:
    -15°C - +90°C
  • Cross Section Area:
    1C: 10-1000mm²
    2-5C: 1.5-400mm/C²
    6C: 6mm²/C
    7C: 1.5-35mm²/C
  • Catalog:
  • Certification:
Applicable and Compliant Standards:

XLPE Insulated, LSOH Sheathed, Aluminum Wire Armour(AWA) Cable

  • Standard:
    BS 6724
  • Certification Body:
    BASEC
  • Structure:
    Cu / XLPE / AWA / LSOH
  • Type:
    6941B
  • Core:
    1
  • Operating Voltage Range:
    600/1000V
  • Operating Temperature:
    -15°C - +90°C
  • Cross Section Area:
    50-1000mm²
  • Catalog:
  • Certification:
Applicable and Compliant Standards:

XLPE Insulated, LSOH Sheathed, Galvanized Steel Wire Armour(SWA) Cable

  • Standard:
    BS 6724
  • Certification Body:
    BASEC
  • Structure:
    Cu / XLPE / SWA / LSOH
  • Type:
    6942B, 6943B, 6944B, 6945B
  • Core:
    2, 3, 4, 5, 7, 12, 19, 27, 37
  • Operating Voltage Range:
    600/1000V
  • Operating Temperature:
    -15°C - +90°C
  • Cross Section Area:
    2-4C: 1.5-400mm²/C
    5C: 1.5-70mm²/C
    ≥7C: 1.5-4mm²/C
  • Catalog:
  • Certification:
Applicable and Compliant Standards:

Fire Resistant, LSOH Insulated with Mica/Glass Tape, Non-sheathed Cable

  • Standard:
    BS 8592
  • Certification Body:
    BASEC
  • Certified Specs:
    1C: 1.5-70mm²/C
  • Structure:
    FR / Cu / LSOH
  • Fire Resistance Test Standard:
    BS 6387 CWZ
  • Operating Voltage Range:
    450/750V
  • Operating Temperature:
    -15°C - +90°C
  • Cross Section Area:
    1.5-400mm²
  • Catalog:
  • Certification:
  • FSD Letter:
Applicable and Compliant Standards:

Fire Resistant, XLPE Insulated with Mica/Glass Tape, LSOH Sheathed, Galvanized Steel Wire Armour (SWA) Cable (F2)

  • Standard:
    BS 7846-F2
  • Certification Body:
    BASEC
  • Certified Specs:
    2-4C: 1.5-400mm²/C
    5C: 1.5-70mm²/C
    ≥7C: 1.5-4mm²/C
  • Regulatory Approval:
    Hong Kong Fire Services Department
  • Approval Specs:
    2-4C: 1.5-400mm²
  • Structure:
    FR / Cu / XLPE / SWA / LSOH
  • Core:
    2, 3, 4, 7, 12, 19, 27, 37
  • Fire Resistance Category:
    BS 7846 Category F2
  • Operating Voltage Range:
    600/1000V
  • Operating Temperature:
    -15°C - +90°C
  • Cross Section Area:
    2-4C: 1.5-400mm²/C
    5C: 1.5-70mm²/C
    ≥7C: 1.5-4mm²/C
  • Catalog:
  • Certification:
  • FSD Letter:
Applicable and Compliant Standards:

Fire Resistant, XLPE Insulated with Mica/Glass Tape, LSOH Sheathed, Galvanized Steel Wire Armour (SWA) Cable (F120)

  • Standard:
    BS 7846-F120
  • Certification Body:
    BASEC
  • Certified Specs:
    2-3C: 10-400mm²/C
    4C: 4-400mm²/C
  • Regulatory Approval:
    Hong Kong Fire Services Department
  • Approval Specs:
    2-3C: 10-400mm²
    4C: 4-400mm²
  • Structure:
    FR / Cu / XLPE / SWA / LSOH
  • Core:
    2, 3, 4
  • Fire Resistance Category:
    BS 7846 Category F120
  • Operating Voltage Range:
    600/1000V
  • Operating Temperature:
    -15°C - +90°C
  • Cross Section Area:
    2-3C: 10-400mm²/C
    4C: 4-400mm²/C
  • Catalog:
  • Certification:
  • FSD Letter:
Applicable and Compliant Standards:

PE Insulated, PVC Sheathed, Individual+Overall Screened, Galvanized Steel Wire Armour (SWA) Instrumentation Cable

  • Standard:
    BS EN 50288-7
  • Structure:
    Cu / PE / IS / OS / PVC / SWA / PVC
  • Operating Voltage Range:
    <2.5mm²: 300V
    2.5mm²: 500V
  • Operating Temperature:
    -25°C - +80°C
  • Cross Section Area:
    0.5-2.5mm²
  • Number Of Pair:
    1, 2, 4, 5, 6, 10, 12, 15, 20, 24
  • Catalog:
Applicable and Compliant Standards:

XLPE Insulated, PVC Sheathed, Individual+Overall Screened, Galvanized Steel Wire Armour (SWA)

  • Standard:
    BS EN 50288-7
  • Structure:
    Cu / XLPE / IS / OS / PVC / SWA / PVC
  • Operating Voltage Range:
    <2.5mm²: 300V
    2.5mm²: 500V
  • Operating Temperature:
    -25°C - +80°C
  • Cross Section Area:
    0.5-2.5mm²
  • Number Of Pair:
    1, 2, 4, 5, 6, 10, 12, 15, 20, 24
  • Catalog:
Applicable and Compliant Standards:

XLPE Insulated, LSOH Sheathed, Individual+Overall Screened, Galvanized Steel Wire Armour (SWA)

  • Standard:
    BS EN 50288-7
  • Structure:
    Cu / XLPE / IS / OS / LSOH / SWA / LSOH
  • Operating Voltage Range:
    300V@<2.5mm²
    [email protected]²
  • Operating Temperature:
    -25°C - +80°C
  • Cross Section Area:
    0.5-2.5mm²
  • Number Of Pair:
    1, 2, 4, 5, 6, 10, 12, 15, 20, 24
  • Catalog:
Applicable and Compliant Standards:

XLPE Insulated, PVC Sheathed, Prefabricated Branch Cable

  • Standard:
    JIS C 2810, BS 7889
  • Certification Body:
    BASEC (BS 7889 Only)
  • Structure:
    Cu / XLPE / PVC
  • Operating Voltage Range:
    600/1000V
  • Operating Temperature:
    -15°C - +90°C
  • Main Cross Section Area:
    70-630mm²
  • Branch Cable Cross Section Area:
    10-185mm²
  • Catalog:
  • Certification:
Applicable and Compliant Standards:

XLPE Insulated, LSOH Sheathed, Prefabricated Branch Cable

  • Standard:
    JIS C 2810, BS 8573
  • Certification Body:
    BASEC (BS 8573 Only)
  • Structure:
    Cu / XLPE / LSOH
  • Operating Voltage Range:
    600/1000V
  • Operating Temperature:
    -15°C - +90°C
  • Main Cross Section Area:
    70-630mm²
  • Branch Cable Cross Section Area:
    10-185mm²
  • Catalog:
  • Certification:
Applicable and Compliant Standards:

Category 5E U/UTP 100Mhz

  • Standard:
    ISO/IEC 11801 Class D
  • Structure:
    Cu / HDPE / PVC
  • Number Of Pair:
    4
  • Operating Temperature:
    -20°C - +60°C
  • Cross Section Area:
    24 AWG
  • Catalog:
  • Test Report:
Applicable and Compliant Standards:

Category 6 U/UTP 250Mhz

  • Standard:
    ISO/IEC 11801 Class E
  • Structure:
    Cu / HDPE / PVC
  • Number Of Pair:
    4
  • Operating Temperature:
    -20°C - +60°C
  • Cross Section Area:
    23 AWG
  • Catalog:
  • Test Report:
Applicable and Compliant Standards:

PVC Insulated, PVC Sheathed Cable

  • Standard:
    BS EN 50525-2-11
  • Certification Body:
    ECM
  • Structure:
    Cu / PVC / PVC
  • Type:
    3182Y, 3183Y, 3184Y, 3185Y, H05VV-F
  • Core:
    2, 3, 4, 5
  • Operating Voltage Range:
    300/500V
  • Operating Temperature:
    -15°C - +70°C
  • Cross Section Area:
    0.75-4mm²
  • Catalog:
  • Certification:
Applicable and Compliant Standards:

TPR Insulated, TPR Sheathed Flexible Cable (Ordinary Duty)

  • Standard:
    IEC 60245
  • Certification Body:
    ISET
  • Structure:
    Cu / TPR / TPR
  • Type:
    YZ
  • Core:
    2, 3, 4, 5
  • Operating Voltage Range:
    300/500V
  • Operating Temperature:
    -25°C - +60°C
  • Cross Section Area:
    0.75-6mm²
  • Catalog:
  • Certification:
Applicable and Compliant Standards:

TPR Insulated, TPR Sheathed Flexible Cable (Heavy Duty)

  • Standard:
    IEC 60245
  • Certification Body:
    ISET
  • Structure:
    Cu / TPR / TPR
  • Type:
    YC
  • Core:
    2, 3, 4, 5
  • Operating Voltage Range:
    450/750V
  • Operating Temperature:
    -25°C - +60°C
  • Cross Section Area:
    1.5-35mm²
  • Catalog:
  • Certification:
Applicable and Compliant Standards: